Must be able Must be able to access all Navy installations and other shipyards by obtaining DBIDS and NAVSEA badges.
Must be proficient in the applicable NAVSEA Standard Items, OSHA standards, NSTM's, and regulatory body regulations.
Must be proficient at reading and interpreting electrical schematics.
Must be proficient at planning, laying-out and installing Temporary Service equipment and cabling IAW NSI.
Must be proficient at the use of VOMs, Meggers, Amp and Phase rotation meters, etc. in-way of trouble-shooting, testing and circuit analysis.
Must be proficient at building, maintaining, troubleshooting and diagnosing electrical problems to component level on Temporary Service Electrical equipment.
Must be proficient in setting up Temporary Electrical Service Generators and Power Mods IAW all NASSCO and Government requirements.
Must be proficient in adhering to the requirements of NAVSEA Standard Items 009-08, 009-28 and 009-74 on installation and maintaining of Temporary Services on board ship and on piers.
Must have well-defined knowledge of building, maintaining, troubleshooting and diagnosing electrical problems to component level on Temporary Service Electrical equipment with minimum guidance of a supervisor or lead electrician.
Must possess a fundamental understanding of setting up Temporary Electrical Service Generators and Power Mods IAW all NASSCO and Government requirements.
Must have a working knowledge of NAVSEA Standard Items 009-08, 009-28 and 009-74 and how each correlates to the installation and maintaining of Temporary Services on board ship and on piers.
Must have all necessary basic hand-tools on shop list to accomplish any task on hand and excellent knowledge on the correct use of each tool.
Must know applicable NAVSEA Standard Item, OSHA standards, and regulatory body regulations.
Must be proficient at reading and interpreting schematics with minimum guidance of a supervisor or lead electrician.
Must be capable of laying-out and installing Temporary Service Electrical equipment and cabling with minimum guidance of a supervisor or lead electrician.
Must have a good fundamental understanding on how to use electrical test equipment in-way of trouble-shooting, testing and circuit analysis of Temporary Service Electrical equipment.
Must have a working knowledge on ship's compartmental layout.
Must have all necessary hand-tools to accomplish any task on hand and satisfactory working knowledge on the correct use of each tool.
Must be familiar with applicable NAVSEA Standard Items, OSHA standards, and regulatory body regulations
Must possess a fundamental knowledge of reading and interpreting electrical schematics with guidance of a supervisor or lead electrician.
Must have a basic understanding of NAVSEA Standard Items 009-08, 009-28 and 009-74 and how each correlates to the installation and maintaining of Temporary Services on board ship and on piers.
Must be able to work in all locations where work is required, including but not limited to tanks, voids, cofferdams and elevated locations.
Must have Rapid Gate access or be eligible to obtain Rapid Gate access.
Must be able to understand, read and write proficiently in English.
Must have current WAF training.